Abstract
A large percentage of building energy consumption is for the maintenance of indoor thermal comfort conditions in different climatic conditions, particularly in hot and humid climates. Typical heating, ventilating and air-conditioning systems present an expensive source of energy or electric energy consumption. However, these processes have possible alternatives, materials and energy sources that are more economical and environmental friendly to support the building’s indoor thermal environment. The application of hydrophilic liquid desiccant materials or absorbents can potentially support the maintenance of a comfortable and healthy indoor environment by controlling the air temperature, humidity and air quality. Many absorbent materials are being developed, tested and applied for absorbent-based heating, ventilating and air-conditioning systems. The design of these systems depends on the application and situation. Hence, the systems installed in actual buildings in different climates show their applicability and viability. Because buildings today require an increasing amount of energy for heating, ventilating and air-conditioning, the application of absorbent-based heating, ventilating and air-conditioning systems presents a potential alternative to costly traditional systems. These absorbent-based systems can lessen the building’s energy consumption for the maintenance of its indoor environment. These systems also eliminate chemical contents in the air, such as VOCs, and biological microorganisms, such as bacteria and viruses. Hence, absorbent-based air handling systems are a potential alternative to typical air handling systems. These systems have several advantages: they are cheaper, smaller, require simpler maintenance and can operate on available energy sources. Therefore, further research and studies are needed to address the above issues and simultaneously educate the public (ordinary users) and developing countries on the benefits and advantages of using absorbent-based air-conditioning systems as alternatives to the widely used and established systems.

Suggested Citation

  • Enteria, Napoleon & Yoshino, Hiroshi & Mochida, Akashi, 2013. "Review of the advances in open-cycle absorption air-conditioning systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 28(C), pages 265-289.
  • Handle: RePEc:eee:rensus:v:28:y:2013:i:c:p:265-289
    DOI: 10.1016/j.rser.2013.07.012
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S1364032113004577
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.rser.2013.07.012?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Li, Xiu-Wei & Zhang, Xiao-Song & Quan, Shuo, 2011. "Single-stage and double-stage photovoltaic driven regeneration for liquid desiccant cooling system," Applied Energy, Elsevier, vol. 88(12), pages 4908-4917.
    2. Radhwan, A.M. & Gari, H.N. & Elsayed, M.M., 1993. "Parametric study of a packed bed dehumidifier/regenerator using CaCl2 liquid desiccant," Renewable Energy, Elsevier, vol. 3(1), pages 49-60.
    3. Bergero, Stefano & Chiari, Anna, 2011. "On the performances of a hybrid air-conditioning system in different climatic conditions," Energy, Elsevier, vol. 36(8), pages 5261-5273.
    4. Xiong, Z.Q. & Dai, Y.J. & Wang, R.Z., 2010. "Development of a novel two-stage liquid desiccant dehumidification system assisted by CaCl2 solution using exergy analysis method," Applied Energy, Elsevier, vol. 87(5), pages 1495-1504, May.
    5. Lychnos, G. & Davies, P.A., 2012. "Modelling and experimental verification of a solar-powered liquid desiccant cooling system for greenhouse food production in hot climates," Energy, Elsevier, vol. 40(1), pages 116-130.
    6. Gao, W.Z. & Liu, J.H. & Cheng, Y.P. & Zhang, X.L., 2012. "Experimental investigation on the heat and mass transfer between air and liquid desiccant in a cross-flow dehumidifier," Renewable Energy, Elsevier, vol. 37(1), pages 117-123.
    7. Peng, Donggen & Zhang, Xiaosong, 2011. "Modeling and simulation of solar collector/regenerator for liquid desiccant cooling systems," Energy, Elsevier, vol. 36(5), pages 2543-2550.
    8. Bassuoni, M.M., 2011. "An experimental study of structured packing dehumidifier/regenerator operating with liquid desiccant," Energy, Elsevier, vol. 36(5), pages 2628-2638.
    9. Hassan, A.A.M. & Hassan, M. Salah, 2008. "Dehumidification of air with a newly suggested liquid desiccant," Renewable Energy, Elsevier, vol. 33(9), pages 1989-1997.
    10. Abdul-Wahab, S.A. & Zurigat, Y.H. & Abu-Arabi, M.K., 2004. "Predictions of moisture removal rate and dehumidification effectiveness for structured liquid desiccant air dehumidifier," Energy, Elsevier, vol. 29(1), pages 19-34.
    11. Sultan, G.I. & Hamed, Ahmed M. & Sultan, A.A., 2002. "The effect of inlet parameters on the performance of packed tower-regenerator," Renewable Energy, Elsevier, vol. 26(2), pages 271-283.
    12. Audah, N. & Ghaddar, N. & Ghali, K., 2011. "Optimized solar-powered liquid desiccant system to supply building fresh water and cooling needs," Applied Energy, Elsevier, vol. 88(11), pages 3726-3736.
    13. Enteria, Napoleon & Mizutani, Kunio, 2011. "The role of the thermally activated desiccant cooling technologies in the issue of energy and environment," Renewable and Sustainable Energy Reviews, Elsevier, vol. 15(4), pages 2095-2122, May.
    14. Kumar, Ritunesh & Dhar, P.L. & Jain, Sanjeev, 2011. "Development of new wire mesh packings for improving the performance of zero carryover spray tower," Energy, Elsevier, vol. 36(2), pages 1362-1374.
    15. Peng, Donggen & Zhang, Xiaosong, 2011. "An analytical model for coupled heat and mass transfer processes in solar collector/regenerator using liquid desiccant," Applied Energy, Elsevier, vol. 88(7), pages 2436-2444, July.
    16. Mei, L. & Dai, Y.J., 2008. "A technical review on use of liquid-desiccant dehumidification for air-conditioning application," Renewable and Sustainable Energy Reviews, Elsevier, vol. 12(3), pages 662-689, April.
    17. Peng, Donggen & Zhang, Xiaosong, 2009. "Modeling and performance analysis of solar air pretreatment collector/regenerator using liquid desiccant," Renewable Energy, Elsevier, vol. 34(3), pages 699-705.
    18. Desideri, Umberto & Proietti, Stefania & Sdringola, Paolo, 2009. "Solar-powered cooling systems: Technical and economic analysis on industrial refrigeration and air-conditioning applications," Applied Energy, Elsevier, vol. 86(9), pages 1376-1386, September.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Abdel-Salam, Mohamed R.H. & Ge, Gaoming & Fauchoux, Melanie & Besant, Robert W. & Simonson, Carey J., 2014. "State-of-the-art in liquid-to-air membrane energy exchangers (LAMEEs): A comprehensive review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 39(C), pages 700-728.
    2. Elsarrag, Esam & Igobo, Opubo N. & Alhorr, Yousef & Davies, Philip A., 2016. "Solar pond powered liquid desiccant evaporative cooling," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 124-140.
    3. Abdel-Salam, Mohamed R.H. & Fauchoux, Melanie & Ge, Gaoming & Besant, Robert W. & Simonson, Carey J., 2014. "Expected energy and economic benefits, and environmental impacts for liquid-to-air membrane energy exchangers (LAMEEs) in HVAC systems: A review," Applied Energy, Elsevier, vol. 127(C), pages 202-218.
    4. Giampieri, Alessandro & Ma, Zhiwei & Smallbone, Andrew & Roskilly, Anthony Paul, 2018. "Thermodynamics and economics of liquid desiccants for heating, ventilation and air-conditioning – An overview," Applied Energy, Elsevier, vol. 220(C), pages 455-479.
    5. Gurubalan, A. & Maiya, M.P. & Geoghegan, Patrick J., 2019. "A comprehensive review of liquid desiccant air conditioning system," Applied Energy, Elsevier, vol. 254(C).
    6. Cihan, Ertuğrul & Kavasoğulları, Barış & Demir, Hasan, 2017. "Enhancement of performance of open liquid desiccant system with surface additive," Renewable Energy, Elsevier, vol. 114(PB), pages 1101-1112.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Abdel-Salam, Ahmed H. & Simonson, Carey J., 2016. "State-of-the-art in liquid desiccant air conditioning equipment and systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 1152-1183.
    2. Xie, Ying & Zhang, Tao & Liu, Xiaohua, 2016. "Performance investigation of a counter-flow heat pump driven liquid desiccant dehumidification system," Energy, Elsevier, vol. 115(P1), pages 446-457.
    3. Shukla, Dhruvin L. & Modi, Kalpesh V., 2017. "A technical review on regeneration of liquid desiccant using solar energy," Renewable and Sustainable Energy Reviews, Elsevier, vol. 78(C), pages 517-529.
    4. Wen, Tao & Lu, Lin, 2019. "A review of correlations and enhancement approaches for heat and mass transfer in liquid desiccant dehumidification system," Applied Energy, Elsevier, vol. 239(C), pages 757-784.
    5. Giampieri, Alessandro & Ma, Zhiwei & Ling-Chin, Janie & Bao, Huashan & Smallbone, Andrew J. & Roskilly, Anthony Paul, 2022. "Liquid desiccant dehumidification and regeneration process: Advancing correlations for moisture and enthalpy effectiveness," Applied Energy, Elsevier, vol. 314(C).
    6. Su, Wei & Lu, Zhifei & She, Xiaohui & Zhou, Junming & Wang, Feng & Sun, Bo & Zhang, Xiaosong, 2022. "Liquid desiccant regeneration for advanced air conditioning: A comprehensive review on desiccant materials, regenerators, systems and improvement technologies," Applied Energy, Elsevier, vol. 308(C).
    7. Yin, Yonggao & Qian, Junfei & Zhang, Xiaosong, 2014. "Recent advancements in liquid desiccant dehumidification technology," Renewable and Sustainable Energy Reviews, Elsevier, vol. 31(C), pages 38-52.
    8. Mohammad, Abdulrahman Th. & Mat, Sohif Bin & Sopian, K. & Al-abidi, Abduljalil A., 2016. "Review: Survey of the control strategy of liquid desiccant systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 250-258.
    9. Shukla, D.L. & Modi, K.V., 2022. "Influence of distinct input parameters on performance indices of dehumidifier, regenerator and on liquid desiccant-operated evaporative cooling system – A critical review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 168(C).
    10. Elsarrag, Esam & Igobo, Opubo N. & Alhorr, Yousef & Davies, Philip A., 2016. "Solar pond powered liquid desiccant evaporative cooling," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 124-140.
    11. Peng, Donggen & Zhang, Xiaosong, 2016. "Experimental investigation on regeneration performance, heat and mass transfer characteristics in a forced solar collector/regenerator," Energy, Elsevier, vol. 101(C), pages 296-308.
    12. Angrisani, Giovanni & Roselli, Carlo & Sasso, Maurizio, 2015. "Experimental assessment of the energy performance of a hybrid desiccant cooling system and comparison with other air-conditioning technologies," Applied Energy, Elsevier, vol. 138(C), pages 533-545.
    13. Yang, C.M. & Chen, C.C. & Chen, S.L., 2013. "Energy-efficient air conditioning system with combination of radiant cooling and periodic total heat exchanger," Energy, Elsevier, vol. 59(C), pages 467-477.
    14. Song, Xia & Zhang, Lun & Zhang, Xiaosong, 2019. "Analysis of the temperatures of heating and cooling sources and the air states in liquid desiccant dehumidification systems regenerated by return air," Energy, Elsevier, vol. 168(C), pages 651-661.
    15. Wang, Xinli & Cai, Wenjian & Lu, Jiangang & Sun, Youxian & Ding, Xudong, 2013. "A hybrid dehumidifier model for real-time performance monitoring, control and optimization in liquid desiccant dehumidification system," Applied Energy, Elsevier, vol. 111(C), pages 449-455.
    16. Abdel-Salam, Mohamed R.H. & Fauchoux, Melanie & Ge, Gaoming & Besant, Robert W. & Simonson, Carey J., 2014. "Expected energy and economic benefits, and environmental impacts for liquid-to-air membrane energy exchangers (LAMEEs) in HVAC systems: A review," Applied Energy, Elsevier, vol. 127(C), pages 202-218.
    17. Rafique, M. Mujahid & Gandhidasan, P. & Bahaidarah, Haitham M.S., 2016. "Liquid desiccant materials and dehumidifiers – A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 56(C), pages 179-195.
    18. Wen, Tao & Luo, Yimo & Wang, Meng & She, Xiaohui, 2021. "Comparative study on the liquid desiccant dehumidification performance of lithium chloride and potassium formate," Renewable Energy, Elsevier, vol. 167(C), pages 841-852.
    19. Li, Xian & Liu, Shuai & Tan, Kok Kiong & Wang, Qing-Guo & Cai, Wen-Jian & Xie, Lihua, 2016. "Dynamic modeling of a liquid desiccant dehumidifier," Applied Energy, Elsevier, vol. 180(C), pages 435-445.
    20. Kashish Kumar & Alok Singh & Saboor Shaik & C Ahamed Saleel & Abdul Aabid & Muneer Baig, 2022. "Comparative Analysis on Dehumidification Performance of KCOOH–LiCl Hybrid Liquid Desiccant Air-Conditioning System: An Energy-Saving Approach," Sustainability, MDPI, vol. 14(6), pages 1-22, March.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:rensus:v:28:y:2013:i:c:p:265-289. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/600126/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.