Inspired by hassio-ecoflow and ecoflow-mqtt-prometheus-exporter this integration uses EcoFlow MQTT Broker mqtt.ecoflow.com
to monitor and control the device.
- Install as a custom repository via HACS
- Manually download and extract to the custom_components directory
Once installed, use Add Integration -> Ecoflow Cloud.
DELTA_2 (sensors: 37, switches: 8, sliders: 6, selects: 5)
Sensors
- Main Battery Level
- Battery Level
- Total In Power
- Total Out Power
- AC In Power
- AC Out Power
- AC In Volts
- AC Out Volts
- Solar In Power
- DC Out Power
- Type-C (1) Out Power
- Type-C (2) Out Power
- USB (1) Out Power
- USB (2) Out Power
- USB QC (1) Out Power
- USB QC (2) Out Power
- Charge Remaining Time
- Discharge Remaining Time
- Inv Out Temperature
- Cycles
- Battery Temperature
- Min Cell Temperature (disabled)
- Max Cell Temperature (disabled)
- Battery Volts (disabled)
- Min Cell Volts (disabled)
- Max Cell Volts (disabled)
- Slave Battery Level (auto)
- Slave Battery Temperature (auto)
- Slave Min Cell Temperature (disabled)
- Slave Max Cell Temperature (disabled)
- Slave Battery Volts (disabled)
- Slave Min Cell Volts (disabled)
- Slave Max Cell Volts (disabled)
- Slave Cycles (auto)
- Slave In Power (auto)
- Slave Out Power (auto)
- Status
Switches
- Beeper
- USB Enabled
- AC Always On
- Prio Solar Charging
- AC Enabled
- X-Boost Enabled
- DC (12V) Enabled
- Backup Reserve Enabled
Sliders (numbers)
- Max Charge Level
- Min Discharge Level
- Backup Reserve Level
- Generator Auto Start Level
- Generator Auto Stop Level
- AC Charging Power
Selects
- DC (12V) Charge Current
- Screen Timeout
- Unit Timeout
- AC Timeout
- DC (12V) Timeout
RIVER_2 (sensors: 24, switches: 3, sliders: 3, selects: 5)
Sensors
- Main Battery Level
- Battery Charging State
- Total In Power
- Total Out Power
- AC In Power
- AC Out Power
- AC In Volts
- AC Out Volts
- Type-C In Power
- Solar In Power
- DC Out Power
- Type-C (1) Out Power
- USB Out Power
- Charge Remaining Time
- Discharge Remaining Time
- Inv Out Temperature
- Cycles
- Battery Temperature
- Min Cell Temperature (disabled)
- Max Cell Temperature (disabled)
- Battery Volts (disabled)
- Min Cell Volts (disabled)
- Max Cell Volts (disabled)
- Status
Switches
- AC Enabled
- X-Boost Enabled
- DC (12V) Enabled
Sliders (numbers)
- Max Charge Level
- Min Discharge Level
- AC Charging Power
Selects
- DC (12V) Charge Current
- DC Mode
- Screen Timeout
- Unit Timeout
- AC Timeout
RIVER_2_MAX (sensors: 27, switches: 5, sliders: 4, selects: 5)
Sensors
- Main Battery Level
- Battery Charging State
- Total In Power
- Total Out Power
- Solar In Current
- Solar In Voltage
- AC In Power
- AC Out Power
- AC In Volts
- AC Out Volts
- Type-C In Power
- Solar In Power
- DC Out Power
- Type-C Out Power
- USB Out Power
- Charge Remaining Time
- Discharge Remaining Time
- Remaining Time
- Inv Out Temperature
- Cycles
- Battery Temperature
- Min Cell Temperature (disabled)
- Max Cell Temperature (disabled)
- Battery Volts (disabled)
- Min Cell Volts (disabled)
- Max Cell Volts (disabled)
- Status
Switches
- AC Enabled
- AC Always On
- X-Boost Enabled
- DC (12V) Enabled
- Backup Reserve Enabled
Sliders (numbers)
- Max Charge Level
- Min Discharge Level
- AC Charging Power
- Backup Reserve Level
Selects
- DC (12V) Charge Current
- DC Mode
- Screen Timeout
- Unit Timeout
- AC Timeout
RIVER_2_PRO (sensors: 25, switches: 3, sliders: 3, selects: 5)
Sensors
- Main Battery Level
- Battery Charging State
- Total In Power
- Total Out Power
- AC In Power
- AC Out Power
- AC In Volts
- AC Out Volts
- Type-C In Power
- Solar In Power
- DC Out Power
- Type-C Out Power
- USB Out Power
- Charge Remaining Time
- Discharge Remaining Time
- Remaining Time
- Inv Out Temperature
- Cycles
- Battery Temperature
- Min Cell Temperature (disabled)
- Max Cell Temperature (disabled)
- Battery Volts (disabled)
- Min Cell Volts (disabled)
- Max Cell Volts (disabled)
- Status
Switches
- AC Enabled
- X-Boost Enabled
- DC (12V) Enabled
Sliders (numbers)
- Max Charge Level
- Min Discharge Level
- AC Charging Power
Selects
- DC (12V) Charge Current
- DC Mode
- Screen Timeout
- Unit Timeout
- AC Timeout
DELTA_PRO (sensors: 40, switches: 6, sliders: 6, selects: 4)
Sensors
- Main Battery Level
- Total In Power
- Total Out Power
- AC In Power
- AC Out Power
- AC In Volts
- AC Out Volts
- Solar In Power
- DC Out Power
- DC Car Out Power
- DC Anderson Out Power
- Type-C (1) Out Power
- Type-C (2) Out Power
- USB (1) Out Power
- USB (2) Out Power
- USB QC (1) Out Power
- USB QC (2) Out Power
- Charge Remaining Time
- Discharge Remaining Time
- Cycles
- Battery Temperature
- Min Cell Temperature (disabled)
- Max Cell Temperature (disabled)
- Battery Volts (disabled)
- Min Cell Volts (disabled)
- Max Cell Volts (disabled)
- Solar In Energy
- Battery Charge Energy from AC
- Battery Charge Energy from DC
- Battery Discharge Energy to AC
- Battery Discharge Energy to DC
- Slave 1 Battery Level (auto)
- Slave 1 Battery Temperature (auto)
- Slave 1 In Power (auto)
- Slave 1 Out Power (auto)
- Slave 2 Battery Level (auto)
- Slave 2 Battery Temperature (auto)
- Slave 2 In Power (auto)
- Slave 2 Out Power (auto)
- Status
Switches
- Beeper
- DC (12V) Enabled
- AC Enabled
- X-Boost Enabled
- AC Always On
- Backup Reserve Enabled
Sliders (numbers)
- Max Charge Level
- Min Discharge Level
- Backup Reserve Level
- Generator Auto Start Level
- Generator Auto Stop Level
- AC Charging Power
Selects
- DC (12V) Charge Current
- Screen Timeout
- Unit Timeout
- AC Timeout
RIVER_MAX (sensors: 34, switches: 4, sliders: 1, selects: 2)
Sensors
- Main Battery Level
- Total In Power
- Total Out Power
- AC In Power
- AC Out Power
- AC In Volts
- AC Out Volts
- DC Out Power
- Type-C Out Power
- USB (1) Out Power
- USB (2) Out Power
- USB (3) Out Power
- Remaining Time
- Cycles
- Battery Temperature
- Min Cell Temperature (disabled)
- Max Cell Temperature (disabled)
- Battery Volts (disabled)
- Min Cell Volts (disabled)
- Max Cell Volts (disabled)
- Solar In Energy
- Battery Charge Energy from AC
- Battery Charge Energy from DC
- Battery Discharge Energy to AC
- Battery Discharge Energy to DC
- Slave Battery Level (auto)
- Slave Battery Temperature (auto)
- Slave Min Cell Temperature (disabled)
- Slave Max Cell Temperature (disabled)
- Battery Volts (disabled)
- Min Cell Volts (disabled)
- Max Cell Volts (disabled)
- Slave Cycles (auto)
- Status
Switches
- Beeper
- AC Enabled
- DC (12V) Enabled
- X-Boost Enabled
Sliders (numbers)
- Max Charge Level (read-only)
Selects
- Unit Timeout
- AC Timeout
RIVER_PRO (sensors: 31, switches: 3, sliders: 1, selects: 2)
Sensors
- Main Battery Level
- Total In Power
- Total Out Power
- Solar In Current
- Solar In Voltage
- AC In Power
- AC Out Power
- AC In Volts
- AC Out Volts
- DC Out Power
- Type-C Out Power
- USB (1) Out Power
- USB (2) Out Power
- USB (3) Out Power
- Remaining Time
- Battery Temperature
- Min Cell Temperature (disabled)
- Max Cell Temperature (disabled)
- Battery Volts (disabled)
- Battery Current (disabled)
- Min Cell Volts (disabled)
- Max Cell Volts (disabled)
- Cycles
- Slave Battery Level (auto)
- Slave Cycles (auto)
- Slave Battery Temperature (auto)
- Slave Battery Volts (disabled)
- Slave Battery Current (disabled)
- Slave Min Cell Volts (disabled)
- Slave Max Cell Volts (disabled)
- Status
Switches
- Beeper (read-only)
- AC Enabled (read-only)
- X-Boost Enabled (read-only)
Sliders (numbers)
- Max Charge Level (read-only)
Selects
- Unit Timeout (read-only)
- AC Timeout (read-only)
DELTA_MINI (sensors: 28, switches: 4, sliders: 3, selects: 4)
Sensors
- Main Battery Level
- Total In Power
- Total Out Power
- AC In Power
- AC Out Power
- AC In Volts
- AC Out Volts
- Solar In Power
- DC Out Power
- DC Car Out Power
- DC Anderson Out Power
- Type-C (1) Out Power
- Type-C (2) Out Power
- USB (1) Out Power
- USB (2) Out Power
- USB QC (1) Out Power
- USB QC (2) Out Power
- Charge Remaining Time
- Discharge Remaining Time
- Cycles
- Battery Temperature (disabled)
- Battery Volts (disabled)
- Solar In Energy
- Battery Charge Energy from AC
- Battery Charge Energy from DC
- Battery Discharge Energy to AC
- Battery Discharge Energy to DC
- Status
Switches
- Beeper
- DC (12V) Enabled
- AC Enabled
- X-Boost Enabled
Sliders (numbers)
- Max Charge Level
- Min Discharge Level
- AC Charging Power
Selects
- DC (12V) Charge Current
- Screen Timeout
- Unit Timeout
- AC Timeout
DELTA_MAX (sensors: 27, switches: 7, sliders: 5, selects: 0)
Sensors
- Main Battery Level
- Battery Level
- Total In Power
- Total Out Power
- AC In Power
- AC Out Power
- AC In Volts
- AC Out Volts
- Solar In Power
- DC Out Power
- Type-C (1) Out Power
- Type-C (2) Out Power
- USB (1) Out Power
- USB (2) Out Power
- USB QC (1) Out Power
- USB QC (2) Out Power
- Charge Remaining Time
- Discharge Remaining Time
- Inv Out Temperature
- Cycles
- Battery Temperature
- Min Cell Temperature (disabled)
- Max Cell Temperature (disabled)
- Battery Volts (disabled)
- Min Cell Volts (disabled)
- Max Cell Volts (disabled)
- Status
Switches
- Beeper
- USB Enabled
- AC Always On
- Prio Solar Charging
- AC Enabled
- X-Boost Enabled
- DC (12V) Enabled
Sliders (numbers)
- Max Charge Level
- Min Discharge Level
- Generator Auto Start Level
- Generator Auto Stop Level
- AC Charging Power
Selects
DELTA_2_MAX (sensors: 27, switches: 5, sliders: 5, selects: 3)
Sensors
- Main Battery Level
- Battery Level
- Total In Power
- Total Out Power
- AC In Power
- AC Out Power
- AC In Volts
- AC Out Volts
- Solar In Power
- DC Out Power
- Type-C (1) Out Power
- Type-C (2) Out Power
- USB (1) Out Power
- USB (2) Out Power
- USB QC (1) Out Power
- USB QC (2) Out Power
- Charge Remaining Time
- Discharge Remaining Time
- Inv Out Temperature
- Cycles
- Battery Temperature
- Min Cell Temperature (disabled)
- Max Cell Temperature (disabled)
- Battery Volts (disabled)
- Min Cell Volts (disabled)
- Max Cell Volts (disabled)
- Status
Switches
- Beeper
- USB Enabled
- AC Always On
- AC Enabled
- X-Boost Enabled
Sliders (numbers)
- Max Charge Level
- Min Discharge Level
- Generator Auto Start Level
- Generator Auto Stop Level
- AC Charging Power
Selects
- Screen Timeout
- Unit Timeout
- AC Timeout
POWERSTREAM beta (sensors: 57, switches: 0, sliders: 0, selects: 0)
Sensors
- Solar 1 Watts
- Solar 1 Input Potential
- Solar 1 Op Potential
- Solar 1 Currrent
- Solar 1 Temperature
- Solar 1 Relay Status
- Solar 1 Error Code (disabled)
- Solar 1 Warning Code (disabled)
- Solar 1 Status (disabled)
- Solar 2 Watts
- Solar 2 Input Potential
- Solar 2 Op Potential
- Solar 2 Current
- Solar 2 Temperature
- Solar 2 Relay Status
- Solar 2 Error Code (disabled)
- Solar 2 Warning Code (disabled)
- Solar 2 Status (disabled)
- Battery Type (disabled)
- Battery Charge
- Battery Input Watts
- Battery Input Potential
- Battery Op Potential
- Battery Input Current
- Battery Temperature
- Charge Time
- Discharge Time
- Battery Error Code (disabled)
- Battery Warning Code (disabled)
- Battery Status (disabled)
- LLC Input Potential (disabled)
- LLC Op Potential (disabled)
- LLC Error Code (disabled)
- LLC Warning Code (disabled)
- LLC Status (disabled)
- Inverter On/Off Status
- Inverter Output Watts
- Inverter Output Potential (disabled)
- Inverter Op Potential
- Inverter Output Current
- Inverter DC Current
- Inverter Frequency
- Inverter Temperature
- Inverter Relay Status
- Inverter Error Code (disabled)
- Inverter Warning Code (disabled)
- Inverter Status (disabled)
- Other Loads
- Smart Plug Loads
- Rated Power
- Lower Battery Limit (disabled)
- Upper Battery Limit (disabled)
- Wireless Error Code (disabled)
- Wireless Warning Code (disabled)
- LED Brightness (disabled)
- Heartbeat Frequency (disabled)
- Status
Switches None
Sliders (numbers) None
Selects None