[go: up one dir, main page]

About: Bio-FET

An Entity of Type: Thing, from Named Graph: http://dbpedia.org, within Data Space: dbpedia.org

A field-effect transistor-based biosensor, also known as a biosensor field-effect transistor (Bio-FET or BioFET), field-effect biosensor (FEB), or biosensor MOSFET, is a field-effect transistor (based on the MOSFET structure) that is gated by changes in the surface potential induced by the binding of molecules. When charged molecules, such as biomolecules, bind to the FET gate, which is usually a dielectric material, they can change the charge distribution of the underlying semiconductor material resulting in a change in conductance of the FET channel. A Bio-FET consists of two main compartments: one is the biological recognition element and the other is the field-effect transistor. The BioFET structure is largely based on the ion-sensitive field-effect transistor (ISFET), a type of metal-

Property Value
dbo:abstract
  • ترانزستور الأثر الحقلي المستشعر الحيوي، هو جهاز استشعار حيوي ذو تأثير ميداني قائم على الترانزستور ذات التأثير الميداني، والمعروف أيضًا باسم ترانزستور تأثير المجال الحيوي (Bio-FET أو BioFET)، أو مستشعر التأثير الميداني (FEB)، أو المستشعر الحيوي MOSFET، هو حقل -ترانزستور ذو تأثير (يعتمد على بنية MOSFET) والذي يتم تحديده من خلال التغيرات في الجهد السطحي الناجم عن ارتباط الجزيئات. عندما ترتبط الجزيئات المشحونة، مثل الجزيئات الحيوية، ببوابة FET، والتي عادةً ما تكون مادة عازلة للكهرباء، يمكنها تغيير توزيع شحنة مادة أشباه الموصلات الأساسية مما يؤدي إلى تغيير في توصيل قناة FET. يتكون Bio-FET من جزأين رئيسيين: أحدهما هو عنصر التعرف البيولوجي والآخر هو ترانزستور التأثير الميداني. يعتمد هيكل BioFET إلى حد كبير على ترانزستور تأثير المجال الحساس للأيونات (ISFET)، وهو نوع من ترانزستور تأثير المجال من أكسيد المعادن وأشباه الموصلات (MOSFET) حيث يتم استبدال البوابة المعدنية بغشاء حساس للأيونات ومحلول إلكتروليت وقطب مرجعي. (ar)
  • A field-effect transistor-based biosensor, also known as a biosensor field-effect transistor (Bio-FET or BioFET), field-effect biosensor (FEB), or biosensor MOSFET, is a field-effect transistor (based on the MOSFET structure) that is gated by changes in the surface potential induced by the binding of molecules. When charged molecules, such as biomolecules, bind to the FET gate, which is usually a dielectric material, they can change the charge distribution of the underlying semiconductor material resulting in a change in conductance of the FET channel. A Bio-FET consists of two main compartments: one is the biological recognition element and the other is the field-effect transistor. The BioFET structure is largely based on the ion-sensitive field-effect transistor (ISFET), a type of metal-oxide-semiconductor field-effect transistor (MOSFET) where the metal gate is replaced by an ion-sensitive membrane, electrolyte solution and reference electrode. (en)
  • FETバイオセンサ (FETbiosensorまたはBio-FET) は、高感度化に加え小型化や集積化にも利点を有する電界効果トランジスタ(FET)を応用したバイオセンサーで、ゲート絶縁膜上に固定されたプローブ分子との特異的な相互作用に基づいて吸着した検出対象物質の電荷を電気信号へ変換する。 (ja)
  • Um biossensor baseado em transistor de efeito de campo, também conhecido como transistor de biosensor de efeito de campo (Bio-FET), biosensor de efeito de campo (FEB), ou biossensor MOSFET, é um transistor de efeito campo (baseado na estrutura MOSFET) que é bloqueado por alterações no potencial de superfície induzido pela ligação de moléculas. Quando moléculas carregadas, como biomoléculas, se ligam à porta FET, que geralmente é um material dielétrico, elas podem alterar a distribuição de carga do material semicondutor subjacente, resultando em uma alteração na condutância do canal FET. (pt)
  • Биотранзистор — это транзистор, основанный на использовании биологически активных полимеров. Используется в сенсорных элементах, биотехнике, медицине, энергетике. (ru)
dbo:thumbnail
dbo:wikiPageID
  • 46185615 (xsd:integer)
dbo:wikiPageLength
  • 22497 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1007354515 (xsd:integer)
dbo:wikiPageWikiLink
dbp:wikiPageUsesTemplate
dct:subject
gold:hypernym
rdfs:comment
  • FETバイオセンサ (FETbiosensorまたはBio-FET) は、高感度化に加え小型化や集積化にも利点を有する電界効果トランジスタ(FET)を応用したバイオセンサーで、ゲート絶縁膜上に固定されたプローブ分子との特異的な相互作用に基づいて吸着した検出対象物質の電荷を電気信号へ変換する。 (ja)
  • Um biossensor baseado em transistor de efeito de campo, também conhecido como transistor de biosensor de efeito de campo (Bio-FET), biosensor de efeito de campo (FEB), ou biossensor MOSFET, é um transistor de efeito campo (baseado na estrutura MOSFET) que é bloqueado por alterações no potencial de superfície induzido pela ligação de moléculas. Quando moléculas carregadas, como biomoléculas, se ligam à porta FET, que geralmente é um material dielétrico, elas podem alterar a distribuição de carga do material semicondutor subjacente, resultando em uma alteração na condutância do canal FET. (pt)
  • Биотранзистор — это транзистор, основанный на использовании биологически активных полимеров. Используется в сенсорных элементах, биотехнике, медицине, энергетике. (ru)
  • ترانزستور الأثر الحقلي المستشعر الحيوي، هو جهاز استشعار حيوي ذو تأثير ميداني قائم على الترانزستور ذات التأثير الميداني، والمعروف أيضًا باسم ترانزستور تأثير المجال الحيوي (Bio-FET أو BioFET)، أو مستشعر التأثير الميداني (FEB)، أو المستشعر الحيوي MOSFET، هو حقل -ترانزستور ذو تأثير (يعتمد على بنية MOSFET) والذي يتم تحديده من خلال التغيرات في الجهد السطحي الناجم عن ارتباط الجزيئات. عندما ترتبط الجزيئات المشحونة، مثل الجزيئات الحيوية، ببوابة FET، والتي عادةً ما تكون مادة عازلة للكهرباء، يمكنها تغيير توزيع شحنة مادة أشباه الموصلات الأساسية مما يؤدي إلى تغيير في توصيل قناة FET. يتكون Bio-FET من جزأين رئيسيين: أحدهما هو عنصر التعرف البيولوجي والآخر هو ترانزستور التأثير الميداني. يعتمد هيكل BioFET إلى حد كبير على ترانزستور تأثير المجال الحساس للأيونات (ISFET)، وهو نوع من ترانزستور تأثير المجال من أك (ar)
  • A field-effect transistor-based biosensor, also known as a biosensor field-effect transistor (Bio-FET or BioFET), field-effect biosensor (FEB), or biosensor MOSFET, is a field-effect transistor (based on the MOSFET structure) that is gated by changes in the surface potential induced by the binding of molecules. When charged molecules, such as biomolecules, bind to the FET gate, which is usually a dielectric material, they can change the charge distribution of the underlying semiconductor material resulting in a change in conductance of the FET channel. A Bio-FET consists of two main compartments: one is the biological recognition element and the other is the field-effect transistor. The BioFET structure is largely based on the ion-sensitive field-effect transistor (ISFET), a type of metal- (en)
rdfs:label
  • ترانزستور الأثر الحقلي المستشعر الحيوي (ar)
  • Bio-FET (en)
  • FETバイオセンサ (ja)
  • Biossensor baseado em transistor de efeito de campo (pt)
  • Биотранзистор (ru)
  • Bio-FET (uk)
owl:sameAs
prov:wasDerivedFrom
foaf:depiction
foaf:isPrimaryTopicOf
is dbo:wikiPageRedirects of
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License