Profils utilisateurs correspondant à "Jonathan M. Behar"
JONATHAN BEHARGuy's and St Thomas' NHS Foundation Trust Adresse e-mail validée de gstt.nhs.uk Cité 2183 fois |
Cardiac resynchronization therapy delivered via a multipolar left ventricular lead is associated with reduced mortality and elimination of phrenic nerve stimulation: long …
Lower Mortality and Eliminated PNS Associated with Quadripolar Leads Introduction Cardiac
resynchronization therapy (CRT) using quadripolar left ventricular (LV) leads provides …
resynchronization therapy (CRT) using quadripolar left ventricular (LV) leads provides …
A publicly available virtual cohort of four-chamber heart meshes for cardiac electro-mechanics simulations
…, O Razeghi, AJ Prassl, EJ Vigmond, JM Behar… - PloS one, 2020 - journals.plos.org
Computational models of the heart are increasingly being used in the development of
devices, patient diagnosis and therapy guidance. While software techniques have been …
devices, patient diagnosis and therapy guidance. While software techniques have been …
[HTML][HTML] Simulating ventricular systolic motion in a four-chamber heart model with spatially varying robin boundary conditions to model the effect of the pericardium
The pericardium affects cardiac motion by limiting epicardial displacement normal to the
surface. In computational studies, it is important for the model to replicate realistic motion, as this …
surface. In computational studies, it is important for the model to replicate realistic motion, as this …
Optimized left ventricular endocardial stimulation is superior to optimized epicardial stimulation in ischemic patients with poor response to cardiac resynchronization …
Objectives : The purpose of this study was to identify the optimal pacing site for the left ventricular
(LV) lead in ischemic patients with poor response to cardiac resynchronization therapy (…
(LV) lead in ischemic patients with poor response to cardiac resynchronization therapy (…
Beneficial effect on cardiac resynchronization from left ventricular endocardial pacing is mediated by early access to high conduction velocity tissue …
Background— Cardiac resynchronization therapy (CRT) delivered via left ventricular (LV)
endocardial pacing (ENDO-CRT) is associated with improved acute hemodynamic response …
endocardial pacing (ENDO-CRT) is associated with improved acute hemodynamic response …
[HTML][HTML] His-bundle and left bundle pacing with optimized atrioventricular delay achieve superior electrical synchrony over endocardial and epicardial pacing in left …
Background His-bundle pacing (HBP) and left bundle pacing (LBP) are emerging as novel
delivery methods for cardiac resynchronization therapy (CRT) in heart failure patients with left …
delivery methods for cardiac resynchronization therapy (CRT) in heart failure patients with left …
Real-time X-MRI-guided left ventricular lead implantation for targeted delivery of cardiac resynchronization therapy
Objectives : This study sought to test the feasibility of a purpose-built, integrated software
platform to process, analyze, and overlay cardiac magnetic resonance (CMR) data in real time …
platform to process, analyze, and overlay cardiac magnetic resonance (CMR) data in real time …
[HTML][HTML] Algorithms for left atrial wall segmentation and thickness–evaluation on an open-source CT and MRI image database
Structural changes to the wall of the left atrium are known to occur with conditions that
predispose to Atrial fibrillation. Imaging studies have demonstrated that these changes may be …
predispose to Atrial fibrillation. Imaging studies have demonstrated that these changes may be …
Mechanistic insights into the benefits of multisite pacing in cardiac resynchronization therapy: the importance of electrical substrate and rate of left ventricular activation
Background Multisite pacing (MSP) of the left ventricle is proposed as an alternative to
conventional single-site LV pacing in cardiac resynchronization therapy (CRT). Reports on the …
conventional single-site LV pacing in cardiac resynchronization therapy (CRT). Reports on the …
[HTML][HTML] Comprehensive use of cardiac computed tomography to guide left ventricular lead placement in cardiac resynchronization therapy
Background Optimal lead positioning is an important determinant of cardiac resynchronization
therapy (CRT) response. Objective The purpose of this study was to evaluate cardiac …
therapy (CRT) response. Objective The purpose of this study was to evaluate cardiac …